GENERATOR
750 kW Generator Rental
Contact Us For Pricing
- Prime Rating: 750 kW
- Standby Rating: 825 kW (for 10% overload capacity)
- Frequency: 60 Hz (or optionally 50 Hz, depending on region)
- Voltage: 480 V three-phase (configurable)
- Phase: 3-phase
Overview
The 750 kW Generator Rental from Curtis Power Solutions delivers reliable, high-capacity power for a wide range of industrial, commercial, and emergency applications. Designed to provide both continuous prime power and dependable standby support, this unit ensures your operations stay uninterrupted, no matter the demand.
Built for flexibility and performance, the generator rental features a sound-attenuated enclosure for quieter operation, robust fuel capacity for extended runtimes, and compatibility with automatic transfer switches (ATS) and remote monitoring systems. Whether powering construction sites, hospitals, data centers, or large-scale events, Curtis Power Solutions’ 750 kW generator rental offers an efficient, safe, and portable power solution.
Specifications
Specifications |
Details |
| Prime Power Rating | 750 kW |
| Standby Power Rating | 825 kW (10% overload capability) |
| Rated Frequency | 60 Hz (50 Hz optional) |
| Voltage | 480 V, 3-phase (customizable) |
| Power Factor | 0.8 lag |
| Fuel Type | Diesel (ULSD recommended) |
| Fuel Tank Capacity | ~2,500 gallons (≈9,500 L) |
| Fuel Consumption | @ 100% Load ~200 gal/h (≈757 L/h) |
| Cooling System | Radiator-cooled, closed circuit with fan |
| Alternator Type | Brushless, IP23, with AVR |
| Control Panel | Digital controller with diagnostics & remote monitoring |
| Sound Level | @ 7 m ≤ 78 dB(A) |
Safety information
- Always ensure the generator is properly grounded in accordance with NFPA (National Electrical Code) guidelines
- Only qualified personnel should perform start-up, shutdown, and maintenance
- Maintain a safe clearance (minimum 1 m) around the radiator and exhaust outlet
- Do not operate in enclosed or poorly ventilated spaces — exhaust contains carbon monoxide
- Use appropriate personal protective equipment (PPE): hearing protection, gloves, eye protection
- Never refuel while the engine is running or hot; wait until it cools down
- Regularly inspect fuel lines, hoses, and connections for leaks
- Monitor oil pressure, coolant temperature, and alarms continuously
- Use only recommended fuel and lubrication per manufacturer guidelines
- Lock out and tag control panels before servicing
- Avoid overloading; ensure proper load balancing across phases
- In case of emergency, use the emergency stop button immediately